Dosing screw pump
Please confirm the flow capacity, feeding pressure, pump type and flow direction
Flow: Under pressure, the flow is proportional to the rotating speed.
Pressure: lt's decided by the pump grade number, normally every range is 0.6 MPa. before using.
Flow Direction: the flow direction is decided by the motor direction. The inlet/outlet is set according to needs.
The inlet/outlet is set according to needs. Normally the port near to the motor is the inlet.
Description
Model | Flow Q(m/h) | Working Pressure(Mpa) | Max Speed n(r/min) | Motor Power p(kw) | (NPSH) r(m) | Inlet Flange Diameter(mm) | OutletFlange Diameter(mm) | Allowable Particle Diameter(mm) | Allowable Fiber Length(mm) |
G10-1 | 0.1 | 0.6 | 960 | 0.55 | 4 | 25 | 25 | 0.8 | 15 |
G10-2 | 1.2 | 0.55 | |||||||
G13-1 | 0.4 | 0.6 | 960 | 0.55 | 25 | 25 | 0.8 | 15 | |
G13-2 | 1.2 | 0.55 | |||||||
G15-1 | 0.6 | 0.6 | 960 | 0.55 | 25 | 25 | 0.8 | 15 | |
G15-2 | 1.2 | 0.55 | |||||||
G20-1 | 0.8 | 0.6 | 960 | 0.75 | 25 | 25 | 1.5 | 25 | |
G20-2 | 1.2 | 1.5 | |||||||
G25-1 | 2 | 0.6 | 960 | 1.5 | 32 | 25 | 2 | 30 | |
G25-2 | 1.2 | 2.2 | |||||||
G30-1 | 5 | 0.6 | 960 | 2.2 | 50 | 40 | 2.5 | 35 | |
G30-2 | 1.2 | 3 |